After image processing has corrected the alignment lines on a quartz wafer, this technology measures the chips inside the wafer. There are optional parameters for specified ID (region), sampling inspection, and total inspection.

Target Product       Crystal Oscillator
CapacityApprox. 1.5 sec/4 pieces (at a measuring time of 0.6 sec/piece). 
ControlPLC & PC
Measurement Device 250B-2 (S&A product)
ContactMulti-layered precision contacts for ultra-small pitches
MeasurementFrequencies and CI values, etc.
Measurement Data OutputMapping on the monitor, CSV file
External Dimensions900(W) x 800(D) x 2000(H)